Manual Indexable Probe Head For Coordinate Measuring Machines
The TESASTAR-i features repeatable and programmable indexing positions coupled with a high-precision, integrated, touch-trigger probe. The indexing capability in 15° increments in both axes allows the stylus to swivel through 168 positions without the need for recalibration. Indexing between positions is an easy, one-handed operation; tactile and visual feedback lets you know when the probe is ready to measure.
Part No.

| Technical Characteristics | ||
| Angular Rotation | A: 0° to 90°, B: ±180° | |
| Increments | 15° | |
| Total Number of Positions | 168 | |
| Position Repeatability | 1.5 µm | |
| Probe Repeatability 1D (2 Sigma)* |
0.35 µm | |
| Adjustable Trigger Force | 0.1 to 0.3 N | |
| Overtravel | X/Y = ±20°, Z = +6 mm | |
| Measuring Directions | ±X, ±Y, +Z | |
| Axis Clamping | Manual, By Two Buttons on the Probe Head | |
* Stylus Length 21 mm; 0.12 N; 8 mm/s
Hexagon Metrology, Inc.
250 Circuit Drive
North Kingstown, RI 02852
USA
Toll Free: 855.4.HEXMET
( 855.443.9638 )
Support: 800.343.7933
Phone: 401.886.2000
Fax: 401.886.2727
| © 2013 Hexagon Metrology is part of Hexagon | Privacy & Terms | Site Map |
Hexagon Metrology offers a comprehensive range of products and services for all industrial metrology applications in sectors such as automotive, aerospace, energy and medical. By empowering our customers to fully control their manufacturing processes, we enhance the quality of products and increase efficiency in manufacturing plants around the world.